MrCool Mini-Split F3 — Compressor Discharge Sensor (TP) Fault
MrCool Mini-Split · Error code F3
What F3 Means
F3 means the compressor discharge temperature sensor (TP thermistor) is open, shorted, or reading a dangerously high temperature. The unit protects the compressor by shutting down.
Symptoms
- Outdoor unit stops
- Poor heating/cooling
- F3 on the display
Common Causes
The TP sensor on the compressor has failed.
A low charge makes the compressor run hot, raising discharge temperature.
How to Fix It
- Power off and reseat the TP sensor connector on the outdoor board.
- If the unit was recently installed/charged, verify the refrigerant charge — low charge causes high discharge temps.
- Replace the sensor if faulty; a persistent high-temp trip needs a technician to check the charge and compressor.