KitchenAid Dryer E2 — Thermistor Shorted
KitchenAid Dryer · Error code E2
What E2 Means
Companion to E1 — the thermistor is reading shorted. The control reads excessively high temperature and aborts heat.
Symptoms
- E2 displayed
- No heat
- Cycle stops
Common Causes
Internal short
Chafed wire shorting to chassis
Board-side failure (rare)
How to Fix It
- Unplug the dryer.
- Inspect the thermistor wiring for any pinch or short to ground.
- Test thermistor resistance — replace if near 0Ω.
- Repair wiring and reassemble.
- Replace the ACU only if sensor and wiring test good.
Parts You May Need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More KitchenAid Dryer Codes
Verified against manufacturer documentation: kitchenaid.com
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician.