Maytag Dishwasher F6E2 — Water Inlet Valve Failure
Maytag Dishwasher · Error code F6E2
What F6E2 Means
The control activated the inlet valve but did not see the expected fill, or the valve is electrically failed. Cycle aborts before wash.
Symptoms
- No fill or very slow fill
- Cycle stalls at start
- Audible buzz from valve area
- Repeated F6E2 after reset
Common Causes
Coil burned open after years of use.
Below ~20 psi the valve doesn't open reliably.
Sediment restricts flow below the threshold.
Connector knocked loose during cabinet work.
How to Fix It
- Power down at the breaker for 5 minutes and retry.
- Verify house water pressure at the kitchen sink (should be 20-120 psi).
- Remove and inspect the inlet screen at the valve; clean any grit.
- With power off, ohm-test the inlet valve solenoid (500-1500 ohms typical).
- Reseat the harness connector at the valve.
- Replace the inlet valve if out of spec or visibly leaking.
Parts You May Need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More Maytag Dishwasher Codes
Verified against manufacturer documentation: maytag.com