Bosch Dishwasher E11 — Temperature sensor (NTC) open or shorted
Bosch Dishwasher · Error code E11
What E11 Means
The NTC temperature sensor is reporting an out-of-range value. Control board cannot trust the temperature reading.
Symptoms
- Cycle stops shortly after start
- No heat phase
- Error appears repeatably at the same step
Common Causes
Resistance way out of spec at known temperature.
Broken or disconnected harness pin to the sensor.
Moisture in the NTC connector causing high resistance.
Rare, but PCB input channel failed.
How to Fix It
- Power off at the breaker.
- Access the heat pump / NTC at the base of the dishwasher.
- Disconnect the NTC and measure resistance at room temp (~50k ohm class).
- Compare to Bosch spec sheet for the model; replace if out of range.
- Reseat the harness connector; clean any corrosion.
- Restore power and verify the cycle completes.
Parts You May Need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More Bosch Dishwasher Codes
Verified against manufacturer documentation: bosch-home.com
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician.